7.2.8. Dismembering plant. Boning. Rooms: The dismembering plant operated under a “boning” category permit must include:(a) a room including:i. a receiving sector for inedible meat;
ii. a treatment sector with separate areas for skinning and eviscerating and for cutting up, boning and colouring the meat; and
iii. a sector for storing packagings and for shipping packaged products;
(b) a refrigerated room with a temperature between 0ºC and 4ºC or, where applicable, a freezing room with a maximum temperature of minus 18ºC for preserving frozen products;
(c) a waste room or compartment refrigerated at a maximum temperature of 7ºC for preserving unused skins, viscera and bones intended for a dismembering plant provided for in sections 7.2.4 or 7.2.5. This room or compartment may be replaced by a separate area reserved for these purposes, inside the room provided for in subparagraph b. The part of this area reserved for skins must be equipped with a 1 m wall;
(d) sanitary rooms equipped with sinks and lavatories for the use of the staff;
(e) an installation for the purification of waste water in conformity with the regulations in force and, where applicable, a trap for organic fat, installed in the dirty sector or outside the dismembering plant;
(f) a machine room or a separate sector including an area for the installation of heating apparatus, compressors, and electric distribution panels and an area for the repair and mechanical maintenance of the equipment;
(g) a compartment for storing cleaning, washing and sanitizing material;
(h) (subparagraph revoked).